An air–bone gap is the number of decibels separating the air-conduction threshold, measured through headphones, from the bone-conduction threshold, measured via a mastoid vibrator, at the same test frequency. Bone conduction bypasses the ear canal, eardrum and ossicles and tests the inner ear directly, so a gap shows how much hearing is being lost in the outer or middle ear. A gap of 10 dB or less is within test error; 15 dB or more at two or more frequencies is considered a true conductive component.
On a pure-tone audiogram, pure sensorineural loss shows the two lines overlapping, conductive loss shows them separated, and a mixed loss shows both a gap and depressed bone thresholds. Common causes of a gap are wax, fluid behind the eardrum, a perforation, a disrupted ossicular chain and otosclerosis.
The size of the gap predicts how much treatment can restore, since only the conductive part is recoverable, and closing it to within 10 dB is how ear surgeons report success after stapes or ossicular surgery. Ask what your average gap is across 500, 1000, 2000 and 4000 Hz, because any proposed operation will be judged against that figure.